The NearStore® VTL 5.2.3 Release Notes contain
links to the latest information and bug fixes for the NetApp NearStore
VTL 5.2.3 release. These Release Notes are designed to be used online.
This section contains information about the following
topics:
New and Changed Features
NearStore VTL 5.2.3 is a GA release in the NearStore
VTL release family and installation is mandatory. This release includes
all of the bug fixes and improvements in the VTL 5.2.2 release,
and includes a bug fix for a problem sometimes seen during disk
and disk shelf firmware upgrades (See Bug ID 256293 in Bugs
Online for more information). Because disk and disk shelf firmware
upgrades might be required to provide fixes for specific problems,
VTL 5.2.3 a mandatory release.
Changes in this release (also included in VTL
5.2.2), include changes or extension to some features and important
fixes intended to improve system reliability and data availability
by doing the following:
- Prevent possible virtual tape data availability problems after
a write error followed by a reboot
- Prevent a VTL from freezing when running into an unexpected
condition
- Support Decru® DataFort® security appliance generation
of encrypted physical tapes
Decru DataFort security appliance support requires the following:
- Running Decru DataFort patch release 2.2 P4 with the compression
option enabled
- Enabling the VTL by setting Advanced > Options Use NetApp
Decru DataFort
Before importing non-encrypted tapes to the VTL, set Advanced
> Options Disable Smart Cloning
You can use a new advanced option to disable smart cloning.
To use this new option from the GUI, do the following: navigate
to Configuration Options > Advanced > Options, and select
Disable Smart Cloning.
- Support new disk and disk shelf firmware
This upgrade is mandatory for all VTL appliances.
Important bug fixes include the following:
- Action 3400 after Disk Shelf Firmware Upgrade or Disk Drive
Firmware Upgrade (Bug ID 256293)
- VTL crashes when over allocation is enabled and running out
of disk space (Bug ID 240608)
- System stops when running disk compression to 6+1 RAID group
(Bug ID 236504)
- I/O errors on compact flash card result in VTL freeze (Bug ID
243395)
- Prevent one physical drive failure from stopping web access
(Bug ID 243101)
- Clicking on a stale browser page causes VTL to crash (Bug ID
242329)
- VTL crashes when doing ACSLS inventory (Bug ID 240314)
- CLI command "acs list_batch_cap", goes into infinite loop (Bug
ID 240311)
- Frequent full inventory update because of missed ACSLS notifications
(Bug ID 242781)
- ACSLS physical tape drive in RECOVERY state causes VTL ACSLS
component to fail (Bug ID 245167)
- Extremely slow backup performance when 180 virtual drives are
configured (Bug ID 245165)
- Action for HTTP autosupport cannot be removed (Bug ID 234889)
- Incorrect drive mapping after configuring a Quantum PX506 series
physical library (Bug ID 242821)
- Starting import through the CLI when the changer is busy causes
VTL crash (Bug ID 247547)
- License lost after disaster recovery and upload of saved configuration
(Bug ID 230904)
- CLI allows creating an import request for an already imported
tape (Bug ID 240748)
- After upgrading from 5.0 to 5.2 and loading the default configuration,
the appliance looses the installed VTL 700 license key (Bug ID
241748)
- VTL forwards backend disk IO errors to the frontend; need error
masking (Bug ID 222282)
- The VTL CLI command "vdrive show" serial number field
is wrong (Bug ID 240103)
- VTL freezes during reboot (Bug ID 201823)
See Bugs Online for more information.
New and changed features include the following:
- Reduction in serial console boot time messages. All routine
messages after the message "All lower priority and informational
console messages are being shut down," are now suppressed.
Note that it can take several minutes after this time before the
boot is complete. You can run the CLI command dmesg show
to check the boot status.
- New support interface to access VTL diagnostics, which is accessible
even if the VTL GUI freezes.
- Support tool to dump the stack of running threads in case of
a VTL freeze.
- After upgrading, a reminder to enable Autosupport, if not already
enabled (an Action Required notification).
To resolve the Action Required notification either enable Autosupport,
or specify that the appliance should not use Autosupport. NetApp
recommends enabling Autosupport.
- Support for AIT drives with Netvault.
- Support for IBM adtt driver for IBM LTO tape drive on HPUX.
- Support for additional virtual drive templates for STK T10000,
IBM 3592, and Quantum DLT-S4 drives.
- Improved support for TSM backup applications.
- Changes to simplify space management for new installations,
including the following:
- Change to the over-allocation default setting. Over-allocation
is now disabled by default.
- Addition of a new virtual drive type designed to optimize
disk space when no physical library is connected to the VTL.
The type has a raw capacity of 50 GB, allocated capacity of
500 GB and smart sizing set to none. Do not use this type
for direct tape creation (DTC).
- Changes to all existing virtual drive types. The revisions
set raw capacity equal to allocated capacity. Typically this
improves disk utilization and permits more effective use of
smart sizing. In some cases, smart sizing may underestimate
the amount of space saved. In those cases, you can turn on
over-allocation to improve disk utilization. Additionally,
if you are not using disk compression, you might want to turn
on over-allocation.
Note that these changes do not affect existing installations.
- Inclusion of disk shelf firmware version 34.
- Support for firmware upgrades to additional drives.
To request more information about an individual bug and to explore
other bug-related tools, see Bugs Online.
Who should upgrade
The NetApp NearStore VTL 5.2.3 release supports all NetApp NearStore
VTL appliances and is mandatory for all VTL appliances to improve
system reliability and data availability.
You can directly upgrade the following releases to the VTL 5.2.3
release:
- VTL 4.1.2 [#6454]
- VTL 5.0 [#6996]
- VTL 5.1.1 [#7990]
- VTL 5.2 [#8466]
- VTL 5.2.1 [#8635]
- VTL 5.2.2 [#9223]
If you have an appliance running VTL 4.1 [#5821], or VTL 4.1.1
[#6233], first upgrade it to VTL 4.1.2 [#6454] before upgrading
to VTL 5.2.3.
If you have an appliance running VTL 5.1 [#7871], first upgrade
it to VTL 5.1.1 [#7990] before upgrading to VTL 5.2.3.
If you are running any other release, for example, an earlier release,
a P release, or a D release, contact NetApp technical support before
upgrading.
Changes to Installation Procedures
The NetApp NearStore VTL 5.2.3 release uses installation procedures
for both the VTL OS, and for disk shelf firmware, that include steps
in addition to the steps documented in the NetApp NearStore
VTL System Administration Guide. Although a disk firmware upgrade
is not required as part of VTL 5.2.3, the disk firmware installation
procedure also now includes some additional steps. The revised procedures
are:
Changes to the VTL OS upgrade procedure
To upgrade the OS on a VTL appliance, do the following:
- Review Who should upgrade.
- Make sure no backup, restore, clone, export, or import operation
is in progress.
- Unload all virtual tapes from the virtual library drives if
any. Use your backup application to do this, if possible. Alternately
go to the Daily Tasks > Virtual Library task in the VTL GUI.
Drag and drop all virtual tapes from drives to empty slots; if
you do this, you need to update your backup application inventory
afterward.
- Save your VTL configuration to a file (Go to Miscellaneous
> Configuration Management > Save Configuration in the VTL
GUI).
- Follow the procedure "Updating the NearStore VTL Software
Image", in the NearStore VTL System Administration Guide.
Changes to the VTL disk shelf
firmware upgrade procedure
Note: Although an action to upgrade the disk shelf firmware is
generated as soon VTL 5.2.3 is installed, the disk shelf firmware
upgrade procedure does not need to be performed immediately, and
can be scheduled for a maintenance window.
Upgrading disk shelf firmware takes approximately 10 minutes per
shelf. Shelves are upgraded sequentially. For example, on a VTL
with four shelves, the process can take up to 40 minutes.
To upgrade VTL disk shelf firmware, do the following:
Caution: Do not interrupt the power to the VTL during the upgrade
process.
Caution: Do not perform any other tasks on the VTL while the upgrade
is in progress, either from a separate admin session, or using the
CLI. The VTL should be idle during the upgrade process.
- Make sure the VTL is idle. There should be no backups, exports,
or clones in progress. Shut down the backup application so that
it does not initiate communication with the VTL. Do not use the
console, either to initiate the upgrade, or for any other reason.
- Make a backup copy of the VTL configuration: from the GUI, select
the Miscellaneous > Configuration Management tab, and then
select Save Configuration.
- Unload all virtual tapes from drives.
- Wait 10 minutes to allow all activity to complete.
- From the VTL GUI, click on the Action Resolve link to go to
the Shelf Firmware Upgrade page, or navigate to the same page
by selecting Support Tools under Configuration Tasks and choosing
the Shelf Firmware Upgrade tab.
- In the list of disk shelves, select the shelves to upgrade,
or select the top checkbox to select all shelves.
- Click Apply. The screen is replaced with the message, "A
Shelf firmware download session is currently in progress."
The screen continues to refresh until the upgrades are complete.
When the upgrades are complete, the GUI displays the Shelf Firmware
Upgrade page. The Controller Version field for the upgraded
shelves lists the new firmware version number.
- When the firmware upgrades are complete, if after 10 minutes
not all of the RAID groups are back to normal, perform these steps:
- Wait ten minutes.
- Power off the VTL head.
- Power off the disk shelves.
- Wait for one minute.
- Power up the disk shelves.
- Wait for two minutes.
- Power up the VTL head.
Note: It is possible that actions will be generated for Raid
Group errors. Ignore these actions as they are due to the shelf
update process itself.
Changes to the VTL disk firmware
upgrade procedure
Upgrading disk firmware takes approximately four minutes per disk.
Disks are upgraded sequentially.
Note: Use this procedure for future disk firmware upgrades. No
updated disk firmware is included with VTL 5.2.3.
To upgrade VTL disk firmware, do the following:
Caution: Do not interrupt the power to the VTL during the upgrade
process.
Caution: Do not perform any other tasks on the VTL while the upgrade
is in progress, either from a separate admin session, or using the
CLI. The VTL should be idle during the upgrade process.
- Make sure the VTL is idle. There should be no backups, exports,
or clones in progress. Shut down the backup application so that
it does not initiate communication with the VTL. Do not use the
console, either to initiate the upgrade, or for any other reason.
- Make a backup copy of the VTL configuration: from the GUI, select
the Miscellaneous > Configuration Management tab, and then
select Save Configuration.
- Unload all virtual tapes from drives.
- Wait 10 minutes to allow all activity to complete.
- Follow the procedure "Starting a Disk Firmware Upgrade",
in the NearStore VTL System Administration Guide.
- When the firmware upgrades are complete, if after 10 minutes,
not all of the RAID groups are back to normal, perform these steps:
- Wait 10 minutes.
- Power off the VTL head.
- Power off the disk shelves.
- Wait for one minute.
- Power up the disk shelves.
- Wait for two minutes.
- Power up the VTL head.
Note: It is possible that actions will be generated for Raid
Group errors. Ignore these actions as they are due to the disk
update process itself.
Links to Product Documentation
The following table describes documents on the
NetApp NOW Web site with the most current information about host
and VTL system requirements, supported configurations, and best
practices, as well as specific procedures that install and manage
your storage environment.
|